Substation / Power Transformer

The substation/Power Transformer is the heart of a substation. Our transformer is designed, manufactured, and tested to high standards of practice as per specification, with quality and reliability. We manufacture both on-load & off-circuit tap switch transformers. This Transformer is generally used for stepping up & down voltage in the transmission network. The transformer tank is suitably designed to allow safe lifting and transportation, effectively sealed for any oil leakage. Transformers are designed & manufactured with due care on health & safety aspects as per respective standards like IEEE, CSA, ANSI, IEC, and NEMA.

Design Capabilities

  • Installation: Outdoor
  • Rating: Upto 150 MVA
  • Voltage: Upto 230 kV or any specific
  • Vector Group: Dyn5, Dyn11, YNyno any specific
  • Type of Cooling: ΟΝΑΝ, ΟΝΑN / ONAF, KNΑΝ, ΚΝΑΝ / KNAF
  • Phase / Frequency: 3 Phase, 50/60 Hz
  • Insulating Fluid: Natural Ester Oil, Synthetic Ester Oil, Mineral Oil as per IEC60296, ASTM D3487
  • Paint: Epoxy, Polyurethane or customer specific
  • Winding Material: Aluminum / Copper
  • Tap Changer: Off Circuit or On Load Tap Changer
  • Applicable Standards: IEEE, CSA, NEMA, DOE, ANSI, IEC 60076

Applications

  • Solar & Wind applications
  • Large Industries
  • Mining stations & Power plants
  • Onshore & Offshore platforms
  • Receiving stations
  • Data centres

Standard Features

  • Mildsteel transformer tank & Cabinets as applicable
  • Rating & Diagram plate
  • On Load Tap Changer / Off Circuit Tap Changer
  • With/Without conservator as per customer specification
  • HV Terminal bushing
  • LV Terminal bushing
  • Radiators
  • Marshalling box with control wiring
  • Inspection cover
  • Filter & Sampling valves
  • Buchholz relay & other protection equipment as required

Special Features

  • Highest dielectric insulation property to withstand lightning impulse
  • Step lap designed CRGO laminations for lower losses & excitation current
  • Pre-heating of coils under vacuum to achieve desired compression height
  • Perma wood clamping rings for uniform compression of primary & secondary winding
  • Adequate ducts between layers, coils, discs for max oil flow & reduced hot spot temperature

Optional Features

  • HV and LV Cable box / Busduct / ATC
  • Winding temperature indicator with WTI CT
  • Surge arrestor / NGR
  • Bi-directional rollers
  • DGPT relay for corrugated tank
  • Rapid pressure rise relay
  • Provision for NIFPS
  • Pulling lugs & jacking pads
  • Isolating valves for radiator
  • Marshalling box for all wirings
  • Magnetic oil gauge with A/T contacts
  • Corrugated / Conventional radiators